1000 Hz probe tone upgrade - PART NUMBER 100689

upgrade-module-100689

Suitable upgrade for:

  • SENTIERO DESKTOP SCREENER
  • SENTIERO DESKTOP DIAGNOSTIC
  • SENTIERO ADVANCED
Main features and benefits:

  • 1000 Hz probe tone upgrade, adds the ability to test younger patients (neonatal ears) as an upgrade to your standard 226Hz probe tone on your device
  • Very cost effective upgrade – if 1000Hz is all that is required, there is no need to upgrade your Class 2 Tympanometer to Class 1, with considerable savings to the buyer.

ABR Binaural Diagnostics - PART NUMBER 100424

(Includes Quick_ screening part number#100337 monaural)

upgrade-module-100424

Suitable upgrade for: SENTIERO ADVANCED

Main features and benefits:

General for ABR:

  • Artifact rejection: weighted averaging, notch filter (50/60 Hz, self-tuning)
  • Residual noise calculation: collecting noise energy from each frame, calculating residual noise level (RMS value in nV)
  • Response detection: auto peak-marker, template matching
  • Normative latencies for different ages & transducer types
  • Display & storage of waveforms, impedance, residual noise, averages; standard + peak marker (editable)
Electrode impedance check:
  • Continuous monitoring of electrode impedance
  • Auto start after impedance OK (optional): R ≤ 4 kΩ, ΔR ≤ 2 kΩ • Sample rate: 48 kHz (stimulus), 16 kHz (response)
ABR diagnostics (order #100424):
  • Stimulus types: Click (0.7 to 6 kHz), Chirp (broadband, 1 to 8 kHz); with ABR-FS license: + Low- Chirp (100 to 850 Hz), Mid-Chirp (850 Hz to 3 kHz), High-Chirp (3 to 10 kHz), Tone Burst (500 Hz, 750 Hz, 1 kHz, 1.5 kHz, 2 kHz, 3 kHz, 4 kHz; waveform: 2 up, 1 plateau, 2 down).
  • Stimulus polarity: condensation, rarefaction, alternating
  • Stimulus rate: 10.1, 20.3, 30.7, 40.3, 69.9, 81.2, 90.4 Hz (default) + user-specific stimulus rate from 10 to 100 Hz; rate mode: 10, 20, 30, 40, 69, 81, 90 Hz
  • Stimulus levels: 0 to max. 95 dB nHL or transducer limits, no stimulus; step size: 5 dB;
  • Rate mode: 10 to 90 dB in steps of 5 dB
  • Masking noise offset levels (white noise): -50 to +50 dB
  • Averages: 1000 up to 20000; step size: 1000
  • Noise stop criterion: 0, 10, 15, 20, 30, 40, 50, 60, 80 nV
  • Automated wave V detection with minimum wave V criterion: 0, 20, 30, 40, 50, 70, 100, 150, 200 nVpp (optional)
  • Plot range (fixed): 0 to inter-stimulus interval + 1.5 ms (minimum 10.5 ms, maximum: 25 ms)
  • Additional parameters: Spread spectrum, auto proceed, auto stop, rate mode
Quick ABR - screening (order #100337 monaural):
  • Stimulus type: Chirp (broadband, 1 to 8 kHz)
  • Stimulus polarity: alternating
  • Stimulus rate: 85 Hz
  • Stimulus level: 35 to 55 dB eHL (step size: 5 dB), ask before test (enables additional stimulus levels 25 and 30 dB eHL)
  • Please note: dB eHL = dB nHL + 10 dB (typical ABR detection threshold for normal hearing subject at 0 dB eHL)
  • Spread spectrum

ASSR module - PART NUMBER 100465

Suitable upgrade for: SENTIERO ADVANCED

Main features and benefits:

Features:

  • Fixed level procedure
  • Adaptive level procedure (threshold estimation)
  • Stimulus bandwidths: 1⁄2 octave, 1 octave, 2 octaves
  • Stimulus rate: 41 ± 1.5 Hz (40 Hz ASSR) and 85 ± 1.5 Hz (80 Hz ASSR), automatic (37 to 163 Hz, dependent on frequency); spread spectrum: ± 2%.
  • Stimulus level fixed: 10 to max. 100 dB nHL or transducer limits; single or multiple level selections possible; step size: 10 dB
  • Stimulus level adaptive: 10 to max. 100 dB nHL or transducer limits; step size: 10 dB
  • Frequencies: 0.25, 0.5, 1, 1.5, 2, 3, 4, 6, 8 kHz (with increasing stimulus bandwidth, less frequencies are available).
  • Response detection: weighted averaging, phase statistics including up to 7 overtones
  • Number of averages: 45 to 900 s; step size: 15 s
  • Noise stop criterion: 0 to 20 nV; step size: 1 nV
  • Display and storage of statistics graph, impedance, artifact threshold, modulation frequency
  • Contralateral masking noise (optional): 0 to 60 dB nHL; step size: 5 dB
  • Electrode impedance check
  • Different protocols defaults
Benefits:
  • It is well known that multiple stimulus frequencies can be applied at the same time binaurally with ASSR. However, the user normally has to choose the setup for sleeping/awake patients or babies/adults.
  • SENTIERO is the first to introduce varying modulation rate from 37 to 163 Hz.
  • Optimized to your individual setup.
  • EEG is analysed and spread spectrum technology is applied to receive the optimal recording conditions and results.
  • ASSR Threshold within a few minutes only.
  • Detailed result views
  • Reports are printed either via label printer or via pdf direct print directly to your PC /office printer.

Class 1 tympanometry module - PART NUMBER 100561

upgrade-module-100561

Suitable upgrade for:

  • SENTIERO DESKTOP DIAGNOSTIC
  • SENTIERO ADVANCED (with TY-MA)
Main features and benefits:
  • 226, 678, 800, 1000 Hz probe tones, with simultaneous presentation
  • Multi-Frequency Reflex’s (226, 678, 904, and 1130 Hz)
  • ESRT module for cochlear implant clinics
  • ETF tests (non) perforated eardrum, Patulus Eustachian tube
  • Pressure range: -600 to +400 daPa
  • Y/B/G components display
  • Tymp + reflex automatic sequence
  • Acoustic reflex frequencies: 500, 1000, 2000, 3000, 4000 Hz
  • Up to 105 dB HL
  • Broadband, High and Low pass noise stimulus up to 90 dB HL
  • Contralateral reflex’s
  • Automatic reflex threshold
  • Entertainment mode available

Class 2 tympanometry module - PART NUMBER 100560

upgrade-module-100560

Suitable upgrade for:

  • SENTIERO DESKTOP SCREENER
  • SENTIERO DESKTOP DIAGNOSTIC
  • SENTIERO ADVANCED
Main features and benefits:
  • 226 Hz probe tone
  • Pressure range: -300 to +300 daPa
  • Y/B/G components display
  • Tymp + reflex automatic sequence
  • Acoustic reflex frequencies: 500, 1000, 2000, 3000, 4000 Hz
  • Up to 100 dB HL
  • Broadband, High and Low pass noise stimulus up to 90 dB HL
  • Ipsilateral reflex
  • Contralateral reflex available with additional transducer
  • Automatic reflex threshold
  • Entertainment mode available
Read more:

DPOAE DIAGNOSTIC module - PART NUMBER 100110

upgrade-module-100110

Suitable upgrade for:

  • SENTIERO DIAGNOSTIC
  • SENTIERO ADVANCED
  • SENTIERO DESKTOP DIAGNOSTIC
Includes:
  • FMDPOAE®, part no. 100536
  • DPHiRES, part no. 100537
Main features and benefits:
  • Test frequencies - 1,1.5, 2, 3, 4, 5, 6, 8 kHz on standard setting; Linear: 0.8 to 10 kHz (step size: 0.5 kHz from 1 to 10 kHz), steps: 10 to 1000 Hz (step size: 10 Hz)- Logarithmic: 0.8 to 10 kHz (step size: 0.5 kHz from 1 to 10 kHz), steps: 1 to 30 points per octave (step size: 1 point per octave)
  • Stimulus levels L2: 30 to 65 dB SPL; step size: 5 dB (single and multiple selections possible)
  • Minimum DPOAE level criterion (optional): -20 to 0 dB; step size: 5 dB
  • Measurement time: adaptive timeout, manual min/max timeout
  • Multi-channel DPOAE - test twice as fast as standard with simultaneous stimulus presentation
  • Cartoon mode – provides visual distraction for younger patients
  • FMDPOAE®feature provides smoother OAE response
  • Selectable SNR stop criteria – 6, 9 or 12dB
  • Save time with the “as fast as possible” setting on stop criteria
  • Probe check feature – 3 individual probe checks to ensure accurate test results
  • In-ear calibration – optimises the stimulus level with ear canal volume adjustment
  • Multiple result screens pages for detailed and diagnostic result analysis

DPOAE SCREENING module - PART NUMBER 100110-Quick

upgrade-module-100110-Quick

Suitable upgrade for:

  • SENTIERO SCREENER
  • SENTIERO DIAGNOSTIC
  • SENTIERO ADVANCED
  • SENTIERO DESKTOP SCREENER
  • SENTIERO DESKTOP DIAGNOSTIC
Main features and benefits:
  • Test frequencies - 2, 3, 4, 5 kHz
  • Multi-channel DPOAE - test twice as fast as standard with simultaneous stimulus presentation
  • Cartoon mode – provides visual distraction for younger patients
  • FMDPOAE® feature provides smoother OAE response
  • electable SNR stop criteria – 6, 9 or 12dB
  • Save time with the “as fast as possible” setting on stop criteria
  • Probe check feature – 3 individual probe checks to ensure accurate test results
  • In-ear calibration – optimises the stimulus level with ear canal volume adjustment
  • Multiple result screens pages for detailed result analysis

DPOAE Threshold Estimation module - objective cochlear audiogram - PART NUMBER 100111

(Includes FMDPOAE® #100536 incl. DPHiRES #100537)

upgrade-module-100111

Suitable upgrade for:

  • SENTIERO DIAGNOSTIC
  • SENTIERO ADVANCED
  • SENTIERO DESKTOP DIAGNOSTIC
Main features and benefits:
  • Frequencies f2: 1, 1.5, 2, 3, 4, 5, 6, 8 kHz
  • Stimulus level L2: 20 to 65 dB SPL (automated threshold detection)
  • Minimum stimulus level L2: 20, 25, 30 dB SPL
  • L2/L1 relation: automatic (scissor paradigm)
  • FMDPOAE® feature provides smoother OAE response
  • Cartoon mode – provides visual distraction for younger patients?
  • Probe check feature – 3 individual probe checks to ensure accurate test results
  • In-ear calibration – optimises the stimulus level with ear canal volume adjustment
  • Multiple result screens pages for detailed result analysis

Electric ABR (eABR) module - PART NUMBER 100901

upgrade-module-100901

Suitable upgrade for: SENTIERO ADVANCED Main features and benefits:

  • Compatible with all cochlear implant systems
  • Selectable recording parameters
  • Trigger cable provided
  • Trigger impulses transmitted from the cochlear implant adapting system
  • Measure up to 15 traces in one test run

Electrocochleography (ECochG) module - PART NUMBER 100464

upgrade-module-100464

Suitable upgrade for: SENTIERO ADVANCED Main features and benefits:

  • Electrode trunk cable allows different ECochG electrode options
  • Click or toneburst stimulus available
  • Selectable intensity level
  • Selectable stimulus rate
  • Separate display of Condensation and Rarefaction
  • Markers for BL, SP, AP and CM
  • Automatic calculation of SP/AP ratio
  • Multiple result screens pages for detailed result analysis

Eustachian Tube Function (ETF) module - PART NUMBER 100913

upgrade-module-100913

Suitable upgrade for:

  • SENTIERO DESKTOP DIAGNOSTIC
  • SENTIERO ADVANCED
Main features and benefits:
Eustachian Tube Function test options:
  • Non-perforated eardrum
  • Perforated Eardrum
  • Patulous Eustachian Tube
Read more:

ABR Binaural Diagnostics - PART NUMBER 100466

(Includes tone burst, freq. spec. chirps (high, mid and low))

upgrade-module-100466

Suitable upgrade for: SENTIERO ADVANCED

Main features and benefits:

General for ABR:

  • Artifact rejection: weighted averaging, notch filter (50/60 Hz, self-tuning)
  • Residual noise calculation: collecting noise energy from each frame, calculating residual noise level (RMS value in nV)
  • Response detection: auto peak-marker, template matching
  • Normative latencies for different age & transducer types
  • Display & storage of waveform, impedance, residual noise, averages; standard + peak marker (editable)
Electrode impedance check:
  • Continuous monitoring of electrode impedance
  • Auto start after impedance OK (optional): R ≤ 4 kΩ, ΔR ≤ 2 kΩ • Sample rate: 48 kHz (stimulus), 16 kHz (response)
Frequency specific ABR Item #100466

Tone burst:
  • Frequency range: 500, 750, 1000, 1500, 2000, 3000, 4000 kHz selectable
  • More frequency-specific than narrow-band chirps but yield lower amplitudes (especially at lower levels).
Chirps (High, Med, Low):
  • Frequency range Low Chirp: 100 Hz - 850 Hz, Mid Chirp: 850 Hz - 3 kHz, High Chirp: 3 kHz – 10 kHz.
  • Chirp evokes higher response amplitudes than click for wave III and V.
  • Narrowband (low-, mid-, high-) chirps Used for a more frequency-specific hearing threshold determination.
  • Masking noise for low- and mid-chirps ipsilateral is presented in order to reduce response contributions from more basal cochlear regions.

High Frequency Audiometry up to 16 kHz - PART NUMBER 100315

(Includes calibrated headphone HDA 300)

upgrade-module-100315

Suitable upgrade for:

  • SENTIERO DIAGNOSTIC
  • SENTIERO ADVANCED
  • SENTIERO DESKTOP DIAGNOSTIC
  • SENTI DESKTOP FLEX
Main features and benefits:
  • For assessing pure-tone thresholds at high frequencies from 9 to 16 kHz.
  • Analysis and assessment of ototoxicity damage
  • PTA-HF is only available with specific headphones, e.g. Sennheiser HDA 300.

MAGIC & MAGIC Screen Interactive children audiometry - PART NUMBER 100112

Multiple-Choice Auditory Graphical Interactive Check

upgrade-module-100112

Suitable upgrade for:

  • SENTIERO ADVANCED
  • SENTIERO DIAGNOSTIC
  • SENTIERO DESKTOP DIAGNOSTIC
  • SENTI DESKTOP FLEX
Main features and benefits:
  • MAGIC is an image-based, self-controlled test which provides a playful alternative to conventional pure-tone audiometry.
  • MAGIC is especially designed for pre-school and school children but can be used for other cooperative subjects as well.
  • MAGIC can be performed at standard audiometric frequencies from 250 Hz to 8 kHz.
  • Different animals represent different frequencies (cow = 250 Hz, bear = 500 Hz, elephant = 1 kHz, cat = 2 kHz, sheep = 3 kHz, mouse = 4 kHz, bird = 5 or 6 kHz, dolphin = 8 kHz.
  • Each animal is presented in three variants: neutral to start the sound presentation, healthy and sick for indicating the two conditions heard and not heard, respectively.
  • Via touch-screen the subject controls the sound presentation and the response if the sound was heard (healthy animal) or not (sick animal).
  • Mute tones are included for detecting incorrect inputs of the subject.
Two MAGIC workflows are available:
  • MAGIC Screen allows quick hearing screening at user-selectable frequencies and levels.
  • MAGIC Audio allows hearing threshold determination at user-selectable frequencies with an automatically controlled bracketing algorithm.

MIRA PC software module - PART NUMBER 100431 for Senti, 100116 for Sentiero

upgrade-module-100116

Suitable upgrade for: All PATH MEDICAL DEVICES Main features and benefits:

  • Imports patients data test results and exports patients data and settings to the instrument via USB
  • Multiple reporting options, printouts and export formats
  • User management and patient management search functions
  • Instrument configuration & firmware update
  • View, compare, comment, print test results
  • Archive and backup

Pure Tone Audiometry Class 3 - PART NUMBER 100347

upgrade-module-100347

Suitable upgrade for:

  • SENTIERO DESKTOP DIAGNOSTIC
  • SENTIERO ADVANCED
  • SENTIERO DIAGNOSTIC
  • SENTI DESKTOP FLEX
Main features and benefits:
  • Frequency range: 0.125, 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4, 5, 6, 8 kHz.
  • Stimulus levels -10 to max 110dB – step size 5dB
  • Fully NOAH compatible
  • Stimulus types: sine, pulsed sine (repetition rate = 2.25 Hz), warble tone (sine modulation, modulation depth = 10 %, fmod = 4 Hz)
  • Minimum stimulus duration (optional): 1.2s
  • Masking noise: third octave noise
  • Automatic audiometric testing: Békésy and Hughson-Westlake
  • Uncomfortable level testing
  • Bilateral audiogram view

Pure Tone Audiometry Class 4 (Advanced) module - PART NUMBER 100653

upgrade-module-100653

Suitable upgrade for:

  • SENTIERO DESKTOP DIAGNOSTIC
  • SENTIERO DESKTOP SCREENER
  • SENTIERO ADVANCED
  • SENTIERO DIAGNOSTIC
  • SENTIERO SCREENER
  • SENTI DESKTOP FLEX
Main features and benefits:
  • Frequency range: 0.125, 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4, 5, 6, 8kHz.
  • Fully NOAH compatible
  • Stimulus levels -10 to max 110dB in 5dB steps
  • Stimulus types: sine, pulsed sine (repetition rate = 2.25 Hz), warble tone (sine modulation, modulation depth = 10 %, fmod = 4 Hz)
  • Minimum stimulus duration (optional): 1.2s

Speech tests software modules

UST: Universal Speech Test adaptable to different languages, using country specific vocabulary.

upgrade-module-ust

Suitable upgrade for: All PATH MEDICAL DEVICES

PART NUMBERS

English based speech tests:

  • Spondee #100463-UT08
  • NU-6 #100463-UT11
  • CID-W22 #100463-UT12
  • PBK-50 #100463-UT13
  • Maryland CNC #100463-UT15
German:
  • Freiburger - #100463-UT02
  • Mouse Test for kids age 5 - 9 yrs for speech development and auditory perception disorder - #100355
Dutch:
  • Dutch speech test - #100919-NL
Hungarian:
  • Hungarian speech test - #100763
Spanish:
  • Logoaudiometria Test (Dr. Tato) - #100463-UT01
Different / multiple languages:
  • CD player - recorded #100919
  • Live Speech (prerequisite: gooseneck microphone) - #100779
  • MATCH Speech test Play interface, imaged base speech test for kids aged 2-5 years - #100356
  • SUN Speech understanding in Noise - #100182
  • BASD (Bochum Auditory Speech Discrimination) Non-verbal screening test - #100538
Read more:

TEOAE DIAGNOSTIC module - PART NUMBER 100109

upgrade-module-100109

Suitable upgrade for:

  • SENTIERO DIAGNOSTIC
  • SENTIERO ADVANCED
  • SENTIERO DESKTOP DIAGNOSTIC
Main features and benefits:
  • Test frequencies – 1,1.5,2, 3, 4 kHz
  • Stimulus level 60-85 dB in 5dB steps
  • Selectable user defined stop criteria 3, 4 or 5 out of 5 frequency band
  • Selectable SNR – 6 or 9dB
  • Stimulus protocol – nonlinear

TEOAE DIAGNOSTIC module - PART NUMBER 100109-Quick

upgrade-module-100109-Quick

Suitable upgrade for:

  • SENTIERO SCREENER
  • SENTIERO DIAGNOSTIC
  • SENTIERO ADVANCED
  • SENTIERO DESKTOP SCREENER
  • SENTIERO DESKTOP DIAGNOSTIC
Main features and benefits:
  • Test frequencies – 0.7 - 4khz – fixed frequency range
  • Stimulus level 85dB peSPL